Thermal performance for indirectely heated storage water heaters (EN 12897)
Scope: The Standard establishes test procedures for characterizing the thermal caracteristics
of indirectly heated unvented (closed ) storage water heaters.
Specific test are:
- Hot water capacity (Clause A.5.1) and reheat performance - Primary Heating Power (Clause A .5.2) test according to the EN12897 -2006 Standard (*)
- Standing heat loss of the store ( Annex B ) according to the EN12897 -2006 Standard (*)
- Same as 1. but for four (4) different flow rates - based on the EN 12897-2006 Standard (*)
- Storage tank heat-loss coefficient (according to the ISO 9459-2 Standard)
(*) Not included in the scope of accreditation
|